At Fukushima Daiichi Nuclear Power Station, we are working on the stabilization of the reactor of Unit 1 by continuing the nitrogen gas injection to the reactor containment vessel and adjusting the water injection rate to the reactor monitoring several parameters. In order to solidify these efforts, we need to install and calibrate a new reactor water level gauge. Also, we need to install a circulating cooling system to improve the status of the reactor to a more stable cooled condition. To do so, we have to improve the working environment inside the reactor building. At this moment, in preparation for the improvement, we are conducting the visual inspection and measuring the radiation dose and the density of radioactive substances by a remote controlled robot inside the reactor building. From now on, we will install an ambient air filtration system
*
, circulate air inside the reactor building for a while, filter the radioactive substances and lower the density. After that, in order for workers to enter the reactor building and conduct necessary works, we will open the airlock. Before opening the airlock, we will monitor the density of the radioactive substances within the reactor building and confirm that the influence to the outside is low enough. We will announce beforehand in opening the airlock of the reactor building. At the same time, we will closely monitor figures at monitoring posts and announce these. * Ambient air filtration system This system vacuums up the ambient air at the work area by a fan, filters impurities and cleans the air.